Network and IP Planning · #11

Online PoE Power Budget Calculator

Checks per-port and total switch power for PoE devices separately.

  • Data is processed in your browser and not sent to a server

Tool

One per line: count; W; label (opt.).

PD: power drawn by the device; cable loss is added. PSE: power allocated by the switch port.

Sets the maximum PSE power per port.

Used only with 'Custom limit'.

PoE budget from the data sheet (e.g. 370 W).

Share of the budget kept in reserve.

What does this tool do?

A PoE design has two separate limits: the per-port limit (what the standard can deliver to one port) and the switch's total PoE budget. Even with enough total power, an AP that exceeds the port limit will not run; even if every device fits its port, the last devices get no power once the budget is used up. The tool checks both.

How to use it

  1. Write count; W; label on each line. Use the maximum consumption from the device data sheet.
  2. Choose whether the value is measured at the switch port (PSE) or the device (PD).
  3. Choose the port standard; for a custom limit choose 'Custom' and enter it.
  4. Enter the switch's total PoE budget and the margin to keep.

Fields

Device groups
One per line: count; W; label (opt.).
Where the watt value applies
PD: power drawn by the device; cable loss is added. PSE: power allocated by the switch port.
Port standard
Sets the maximum PSE power per port.
Custom port limit
Used only with 'Custom limit'.
Switch total PoE budget
PoE budget from the data sheet (e.g. 370 W).
Margin to keep
Share of the budget kept in reserve.

Worked example

InputValue
Device groups
12;15;IP kamera
Where the watt value appliesSwitch port (PSE)
Port standard802.3at (PoE+) – 30 W
Switch total PoE budget240
Margin to keep0

Expected result: 12 × 15 W = 180 W used, 60 W free of a 240 W budget; 15 W per port is within the 802.3at limit of 30 W.

The values are PSE (switch port) values, so no cable loss is added. Four more cameras of this type fit (60 / 15). With a 10 % margin the usable budget would be 216 W and 36 W would remain.

Second scenario

InputValue
Device groups
8;7;IP telefon
6;13;Kamera
4;22;Wi-Fi 6 AP
Where the watt value appliesDevice (PD)
Port standard802.3at (PoE+) – 30 W
Switch total PoE budget370
Margin to keep10

Expected result: 802.3at cable loss (4.5 W) is added to the PD values: 303 W in total; 333 W usable after a 10 % margin, 30 W free. The 22 W AP needs 26.5 W at the PSE and stays within the 30 W limit.

Method and assumptions

IEEE 802.3 PSE port output: af 15.4 W, at 30 W, bt Type 3 60 W, bt Type 4 90 W. The power guaranteed at the PD over 100 m is 12.95 W, 25.5 W, 51 W and 71.3 W.

For PD values the tool calculates PSE need as PD + (PSE − PD), the worst-case loss for 100 m. This is conservative; short cables lose less.

Total = Σ count × per-port PSE power. Usable budget = budget × (1 − margin). Port and budget checks are separate.

Using the result and troubleshooting

Rows over the port limit are red: a higher-class port or an injector is required. If the budget is exceeded, spread devices across switches or add a power supply.

Switches using LLDP-MED dynamic allocation may see lower real consumption. Switches that allocate by class reserve the class maximum per port; enter the class limit as the watt value in that case.

Limits and common mistakes

  • PoE power supply redundancy and PSU failure are not calculated.
  • Inrush current and temperature derating are not considered.
  • Common mistake: entering the average rather than the maximum power of APs with USB or extra radios enabled.

Frequently asked questions

The camera says 12 W — is PoE (af) enough?

If that is the PD value it needs 12 + 2.45 = 14.45 W at the PSE and fits a 15.4 W af port. For outdoor cameras with heaters, check the draw with the heater on.

Related tools and service

Related service: Switch, Router and Network Device Installation

Network online tools · See all online tools